Basic Info.
Conditions
of Use
Car Type, Trailer Type, Marine, Land Use
Usage
Emergency Crew, Standby Unit, Common Units
Cooling
Method
Oil Cooling
Installation
Method
Fixed
Generator
Type
Diesel Generator
Power Consumption
<3W (Standby Mode: ≤ 2W)
Alternator Voltage Input
15V AC - 360 V AC (pH-N)
Alternator Frequency
50 Hz / 60Hz
Transport Package
Standard Packing
Specification
143mm *115mm *41mm
Product Description
LXC3920 spare parts gasoline generator frequency control
LXC3920:Based on LXC3120,add RS232 interface and can be remotely monitored by LXI680
integrated with related PC software.
s Its n main s features e are s as follows:
Display :132×64 LCD with emerald green backlight;
Language :Chinese, English, Spanish and Russian;
Operating :good feeling button pushing, long button life;
Suitable for :3-phase 4-wire, 3-phase 3-wire, single phase 2-wire, and 2-phase 3-wire systems with
voltage 120/240V and frequency 50/60Hz.
Protection: Automatic start/stop of the genset, ATS(Auto Transfer Switch) control with perfect fault
indication and protection function;
Output Control :With ETS, idle control, pre-heat control, speed raise control and speed drop control,
All output ports are relay-out;
Parameter Settings :All the parameters can be adjusted using front panel of the controller or use the
computer through USB to connect directly to controller settings, all is not lost when power down
parameter system;
Sensor Detection :More kinds of curves of temperature, oil pressure, fuel level can be used directly
and users can define the sensor curves by themselves;
Multiple rank Dtisconnect Conditions : s Gens l frequency,speed,oil pressure,D+;
Widely r Power supply range: DC(8~35)V, suitable to different start battery voltage environment;
gounting Assembly :Modular design, anti-flaming ABS plastic enclosure, plug gable connection
terminals and embedded installation way; compact structure with easy mounting.
LXC3920:When mains is abnormal (over/under voltage, loss of phase), enter into "Mains Abnormal
Delay" and LCD displays count down time. When the delay is over, "Start Delay" timer is initiated.
"Start Delay" countdown will be displayed on LCD.
When start delay is over, preheat relay energizes (if configured), "preheat delay XXs" information will
be displayed on LCD.
After the above delay, the Fuel Relay is energized, and then one second later, the Start Relay is
engaged. The engine is cranked for a pre-set time. If the engine fails to fire during this cranking
attempt then the fuel relay and start relay are disengaged for the pre-set rest period; "crank rest time"
begins and wait for the next crank attempt.
Should this start sequence continue beyond the set number of attempts, the start sequence will be
terminated, the first line of LCD display will be highlighted with black and Fail to Start fault will be
displayed.
In case of successful crank attempt, the "Safety On" timer is activated, allowing Low Oil Pressure,
High Temperature, Under speed, Charge Alternator Failure and Aux. inputs (configured) to stabilize
without triggering the fault. As soon as this delay is over, "start idle" delay is initiated (if configured).
During "start idle" delay, under speed, under frequency, under voltage alarms are inhibited. When this
delay is over, "warming up" delay is initiated (if configured).
After the "warming up" delay, if generator status is normal, its indicator will be illuminated. If generator
voltage and frequency have reached on-load requirements, then the generator close relay will be
energized; genset will take load; generator power indicator will illuminate and generator will enter into
Normal Running status. if voltage or frequency is abnorm
LXC3920:During normal running process, if mains normal, enters into "Mains Normal Delay". When
mains indicator illuminates, "Stop Delay" begins.LXC3X10:When the "Remote Start" signal is removed, the stop delay is initiated.
Once this "stop delay" has expired, the Generator Breaker will open and the "Cooling Delay" is then
initiated. After "Transfer Delay", the mains close relay will be energized; mains will take load;
generator power indicator will extinguish while mains power indicator will illuminate.
During "Stop Idle" Delay (if configured), idle relay is energized.
"ETS Solenoid Hold" begins, ETS relay is energized while fuel relay is de-energized.
"Fail to Stop Delay" begins, complete stop is detected automatically.
Generator is placed into its standby mode after its complete stop. Otherwise, fail to stop alarm is
initiated and the corresponding alarm information is displayed on LCD.
Operating Voltage | DC8.0V continuous power supply to 35.0V |
Power consumption | <3W (standby mode: ≤ 2W) |
Alternator voltage input: | 15V AC - 360 V AC (ph-N) |
Phase four-wire | 15V AC - 360 V AC (ph-N) |
Two-phase three-wire | 15V AC - 360 V AC (ph-N) |
Single-phase two-wire | 30V AC - 620 V AC (ph-ph) |
Three-phase three-wire | |
Alternator frequency | 50 Hz / 60Hz |
Speed sensor voltage | 1.0 to 24V (rms) |
Speed sensor frequency | Maximum 10000Hz |
Start relay output | 5A DC28V DC power supply output |
Programmable relay output 1 | 5A DC28V DC power supply output |
Programmable relay output 2 | 5A DC28V DC power supply output |
Programmable relay output 3 | 5A DC28V DC power supply output |
Programmable relay output 4 | 5A AC250V passive output |
Programmable relay output 5 | 5A AC250V passive output |
Dimensions | 143mm x 115mm x41mm |
Hole size | 110mm x 90mm |
Current transformer secondary current | Rated: 5A |
Working conditions | Temperature: (-25 ~ 70) ° C Humidity: (20 ~ 93)% RH |
Storage conditions | Temperature: (-30 ~ +80) ° C |
Protection class | IP55: When installed between the controller and the control panel when the waterproof rubber ring. |
| IP42: When between the controller and the control panel when not fitted waterproof rubber ring. |
Dielectric Strength | Object: Input / Output / Power |
| Reference Standard: IEC688-1992 |
| Test Method: AC1.5Kv/1min leakage current 3mA |
Advantages
MOVE ADVANTAGE |
sales | 4000pcs/month | the fastest transit time | 2days! |
inventory situation | a lauge number of stocks | operational advantages | easy for operation |
production cycle | 1~3days | Service | answer all of your questions within 1day |
Application domain
Apply |
* Biogas Power Generation |
*Natural Gas Power |
*Field Engineering |
*Electric Power |
*Factory |
*Fire-fighting |
Advantages
In line with the quality = life and belief in people-oriented,
continuous improvement of management. Coupled with honesty, pragmatism,
innovation and spirit of the pursuit of the perfect blog for the world each generator to
create an intelligent heart.
Sales | 4000pcs/month | The fastest transit time | 2days! |
Inventory situation | A lauge number of stocks | Operational advantages | Easy for operation |
Production cycle | 1~3days | Service | Answer all of your questions within 1 day |
Packaging & Shipping
Payment Term
1.We accept L/C,D/P,D/A, Alipay, West Union, TT. Cash.
2.All major Credit cards are accepted through secure payment processor ESCROW.
Shipment Term
1. We Ship to Worldwide, except APO/FPO
2. Orders processed timely after showing remittance copy.
3. We only ship to confirmed order addresses. Your order address MUST MATCH your address.
4.Items are shipped from China by Airmail, reach most of the countries within 4 to 20 business days.
5.Delivery time depends on destination and other factors, it may takes up to 20 business days.
6. SERVICE TRANSIT TIME is provided by the carrier and excludes weekends and holidays. Transit times may vary, particularly during the holiday season.
7. If you have not received your shipment within 30 days from payment, please contact us. We will track the shipment and get back to you as soon as possible with a reply. Our goal is customer satisfaction!
Address:
Tuancheng No. 18 Chashang Industrial Zone, Wentang District, Dongcheng District, Dongguan, Guangdong, China
Business Type:
Manufacturer/Factory, Trading Company, Other
Business Range:
Auto, Motorcycle Parts & Accessories, Electrical & Electronics, Industrial Equipment & Components, Instruments & Meters, Manufacturing & Processing Machinery
Management System Certification:
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000
Company Introduction:
Dongguan Tuancheng Automation Equipment Co., Ltd is joint venture with Singapore LIXiSE company. Registered in 2013(formerly known as Dongguan Feirui Electronics Co., Ltd. ) which is located in SI Kai Wei industrial park. Our company is committed to developing, producing and selling in the three series products of generator controller, digital voltage regulator and digital speed governor, which are over than 50 kinds of generator peripheral smart products. We devote ourselves to promoting the application of remote monitoring technology and solutions of systems integration.
Our products are exported to 30 countries and areas such as Southeast Asia, the Middle East and Africa, highly recommended by domestic and foreign customers.
We always adhere to the refined and specialized production management. In 2009 we introduced the NI simulation and automation testing equipment and are the first company to introduce the AOI testing equipment of Intra-industry. It helps us maximum reduce the ricketiness of soldered or welded. Based on the 6 years technology accumulation, we have a world-leading R&D team. Especially the Singapore parallel technology is in the industry-leading position and obtains many national patents. In 2013 the German powerful certification authority award us ISO9001 quality system certification and we also passed CE certification.
Our mission: To promote the development of China′s intelligent generator.
Our vision: To make each generator in the world has an intelligent heart.